This browser does not support the video element.
Installation and operation procedures:
1, check ll the accessories after unpacking, should be complete, no damage before installation.
2. Place the floating boat on a flat ground, press the stainless steel bracket on the screw hole of the floating boat and connect it with bolts.
3. Connect and fix the motor with the stainless steel strut with bolts.
4. Fix one end of the cable input to the power supply along the pull rod and then connect it firmly into the power supply junction box. (Tighten the waterproof joint at the power supply line entrance and wrap it with adhesive tape to strengthen waterproof. )
5. Connect the stainless steel pole with the connecting piece and impeller. The whole machine should move freely, and fasten it on the hole of the floating boat with a rope after inspection.
6. Put the whole machine into the water, and observe whether the water level is equal to the position of the water level scale line in the middle of the impeller, with an error of < 1CM.
Fix the rope so that the pull rod can't move.
7. Turn on the power supply, and the commissioning motor will start instantly and work normally.
8. If the splash is not big, start it again after stopping to ensure the draft of the impeller.
Maintenance and maintenance:
1. Regularly check the working state of the whole machine, especially the fixed state of the fixed rope, to ensure that there is no looseness or fracture.
2. Check the running power supply regularly, and handle it in time if any abnormality is found.
3. If the floating slip is found to have sag, bulge and water leakage (which will affect the normal operation of the impeller), please deal with it in time or replace it.
Fault handling
One: the power protector tripped, and the cause of the failure: the cable was damaged and leaked. Troubleshooting: Check the power cord and cable.Two: the motor does not turn after being electrified, and the cause of the failure is:1. The power supply circuit is in poor contact or loose.2, the voltage is lower than too low3. The draft of the impeller is too deep, and the load is overweight and stuck.Exclusion method:1. Fasten loose power contact points. 2. Measure the voltage.3, check the impeller installation method, or adjust the rope binding the floating ball is not easy to be too tight.Three: the motor is difficult to start or the spray becomes thinner. Cause of failure:1. The power supply voltage is too low. 2. The draft of the impeller is not enough. 3. The impeller has foreign bodies.Elimination method: 1. Measure the voltage. 2, adjust the impeller or elastic fixed rope. 3, remove the impeller winding.
Jiangsu Shangqi Heavy Industry Technology Co. Ltd was established in 2 0 0 2 and is located in the economic development zone of Jingjiang city, enjoying convenient transportation and beautiful environment.